Question 1
What is the primary purpose of a package receipt wipe test?
Correct answer:B
Explanation
Comprehensive and Detailed Explanation: A wipe (swipe) of the external surface of an incoming radioactive package is required to detect removable contamination. The wipe is counted and the result compared with regulatory limits (typically 2 200 dpm/100 cm²). Elevated contamination indicates possible leakage or damage and must be reported to the radiation safety officer and the carrier. The external dose-rate survey measures penetrating radiation but does not detect loose contamination. Technologists must wear gloves, use proper technique, and document both dose-rate and wipe-test results. This procedure protects staff and is a standard regulatory requirement.
Question 2
Which of the following is the correct storage condition for most reconstituted Tc-99m kits?
Correct answer:B
Explanation
Comprehensive and Detailed Explanation: After reconstitution, most Tc-99m kits are stored at room temperature or under refrigeration as specified in the package insert, and they must be used within the stated beyond-use time (often 6–12 hours). Freezing can damage the formulation; excessive heat or light can reduce stability and radiochemical purity. The technologist must record the time of preparation and the expiration time on the vial and on unit-dose labels. Using a kit beyond its expiration time risks reduced labeling efficiency and altered biodistribution. Institutional policies often require radiochemical purity testing near the end of the shelf life or when visual changes are noted.
Question 3
Which of the following is the primary purpose of a center-of-rotation calibration on a SPECT system?
Correct answer:B
Explanation
Comprehensive and Detailed Explanation: Center-of-rotation (COR) calibration determines any offset between the mechanical axis of the gantry and the electronic center of the detector matrix. Small misalignments produce blurring and circular artifacts in reconstructed SPECT images. The calibration is performed with a point or line source at regular intervals and after service. Technologists must verify that the correct COR file is selected for the collimator and orbit type. Accurate COR calibration is essential for high-quality cardiac, brain, and skeletal SPECT studies.
Question 4
Which of the following radionuclides is a pure beta emitter commonly used for therapy?
Correct answer:B
Explanation
Comprehensive and Detailed Explanation: Strontium-89 is a pure beta emitter used for the palliation of bone pain from osteoblastic metastases. Because it emits no gamma photons, it cannot be imaged with a gamma camera and delivers a local radiation dose to bone with minimal external exposure hazard after administration. Tc-99m and I-123 are gamma emitters used for diagnostic imaging; F-18 is a positron emitter. Other pure or predominantly beta emitters used in therapy include P-32, Y-90, and Sm-153 (the latter also emits a low-abundance gamma). Technologists must understand that pure beta emitters require different handling, survey, and patient-release considerations than gamma-emitting radiopharmaceuticals.
Question 5
Which of the following is the standard administered activity range for an adult Tc-99m MAG3 renal scan?
Correct answer:B
Explanation
Comprehensive and Detailed Explanation: The usual adult dose of Tc-99m MAG3 is 5–10 mCi (185–370 MBq). Lower activities may be used in pediatric patients scaled by body weight or surface area. Higher doses increase radiation exposure without proportional diagnostic benefit. Technologists must assay the dose accurately, inject as a bolus for perfusion assessment, and begin dynamic imaging immediately. Proper hydration and timing of furosemide (when used) are critical for accurate interpretation of obstruction. Knowledge of standard dose ranges helps prevent under- or over-dosing and ensures compliance with ALARA principles and institutional protocols.
Question 6
What is the most common cause of a sudden loss of resolution on a gamma camera that previously performed acceptably?
Correct answer:B
Explanation
Comprehensive and Detailed Explanation: Photomultiplier-tube (PMT) gain drift or complete failure is a frequent cause of abrupt degradation in spatial resolution and the appearance of cold spots or distorted images. Temperature changes of a few degrees rarely produce measurable effects on modern cameras. Collimator selection and energy-window settings affect performance but are operator-controlled and would be noticed immediately. Daily flood and resolution checks (bar phantoms) detect such problems before patient imaging. When resolution deteriorates, the technologist should acquire an intrinsic flood and bar-phantom image, inspect the PMT map if available, and contact service. Continued use of a camera with a failed PMT can produce diagnostic errors and must be avoided.
Question 7
Which of the following is the correct patient instruction after administration of a therapeutic dose of I-131?
Correct answer:B
Explanation
Comprehensive and Detailed Explanation: Patients receiving therapeutic I-131 must be given clear written and verbal instructions on radiation precautions. These typically include maintaining distance from others (especially pregnant women and children), sleeping alone, using separate utensils and towels, careful hygiene to avoid contamination from urine and saliva, and the length of time the restrictions apply. The instructions are based on the administered activity and residual dose-rate measurements. Providing and documenting these instructions is a regulatory requirement and an essential part of patient care. Technologists often review the instructions with the patient before release and answer questions to ensure understanding and compliance.
Question 8
Which of the following is the most appropriate radiopharmaceutical for detection of acute cholecystitis?
Correct answer:B
Explanation
Comprehensive and Detailed Explanation: Hepatobiliary scintigraphy with Tc-99m IDA compounds (mebrofenin or disofenin) is the nuclear-medicine study of choice for suspected acute cholecystitis. Non-visualization of the gallbladder despite adequate hepatic uptake and biliary excretion indicates cystic-duct obstruction. Morphine augmentation or delayed imaging may be used when the gallbladder is not seen on early images. Sulfur colloid, MDP, and MAA are not excreted by the hepatobiliary system. Technologists must verify patient fasting status, administer the correct agent, and follow the timed imaging sequence so that the presence or absence of gallbladder filling can be reliably determined.
Question 9
What is the recommended method for monitoring personnel exposure in a nuclear medicine department?
Correct answer:B
Explanation
Comprehensive and Detailed Explanation: Occupational radiation exposure is monitored with personnel dosimeters—typically a whole-body badge worn at the collar or chest and a ring badge worn on the dominant hand under the glove and syringe shield. Dosimeters must be worn whenever working with or around radioactive material, stored away from radiation sources when not in use, and exchanged at the prescribed frequency (usually monthly or quarterly). The results are reviewed by the radiation safety officer and reported to the worker. Blood tests are not a substitute for dosimetry. Proper use and timely return of dosimeters are regulatory requirements and essential components of an ALARA program.
Question 10
Which of the following is the most appropriate action if a daily flood image shows a new, discrete cold defect?
Correct answer:B
Explanation
Comprehensive and Detailed Explanation: A new cold defect on a daily flood most commonly indicates photomultiplier-tube failure, loss of optical coupling, or crystal damage. Continuing to image patients can produce artifacts that mimic disease. The technologist should repeat the flood to confirm the finding. If the defect remains, the camera must be taken out of clinical service until it is repaired and re-qualified. Simply applying an old uniformity map will not correct a hardware failure. Prompt recognition and response protect patients from nondiagnostic studies and are required by quality-assurance standards.
0%
Your score on this page: 0/0
Answer the questions above to see your score.
0 of 90 free Nuclear Medicine questions practiced · - overall accuracy
Our free Nuclear Medicine exam questions sample is your personalized diagnostic tool. Get an instant, honest snapshot of your readiness for the Nuclear Medicine exam and identify the specific topics that need your focus.
What You Get with Full Access:
Complete Question Bank
Mock Exam (Same real exam time and questions)
Smart Performance Dashboard
Identify Weak Spots
Verified Answer & Explanations
Unlimited Reattempts
Mobile-Friendly Study
Regular Content Updates
Nuclear Medicine Complete Package
Choose a plan and prepare with realistic Nuclear Medicine test questions designed to mirror test-day conditions. Every plan includes a full Nuclear Medicine practice exam questions, a timed exam simulator, performance tracking, detailed answer explanations, and the ability to reattempt questions to improve accuracy and confidence.
PracticeTestMaster is an independent exam prep provider. Nuclear Medicine is the property of American Registry of Radiologic Technologists (ARRT).