Skip to main content

Free CBET Exam Questions That Helps Candidates Pass - Page 6

CBET Questions 51-60 of 80 free
0/10 answered · 0 correct

Choose an answer and click Check answer to see if you're right, with the full explanation.

Question 51

Which cybersecurity measure ensures that only authorized users can access a medical device?

Correct answer: B

Explanation

Authentication verifies the identity of users attempting to access a medical device or hospital system. This can involve passwords, biometrics, or multi-factor authentication. Encryption ensures data confidentiality during storage or transmission, firewalls block unauthorized network access, and backups restore data after failures. For CBETs, authentication is crucial because medical devices often store or transmit patient data. Weak authentication measures may allow unauthorized access, leading to HIPAA violations or safety risks if device settings are altered. Technicians may be involved in configuring access controls and ensuring devices integrate with hospital IT authentication systems (e.g., Active Directory).

Question 52

Which type of ultrasound transducer is best suited for cardiac imaging?

Correct answer: C

Explanation

A phased-array transducer is ideal for cardiac imaging because it produces a small footprint and can steer beams electronically to capture rapid heart motion through narrow spaces between ribs. Linear transducers are used for vascular and musculoskeletal imaging, curvilinear for abdominal scans, and pencil probes for Doppler applications. For CBETs, understanding transducer types helps when troubleshooting image quality complaints. Issues such as poor beam steering or weak signals may indicate transducer failure, requiring calibration or replacement. Accurate cardiac imaging is critical for diagnosing arrhythmias, valve disease, and heart failure.

Question 53

Which device measures exhaled carbon dioxide levels to monitor ventilation?

Correct answer: B

Explanation

A capnograph measures exhaled CO₂ levels, providing real-time monitoring of ventilation status. It is especially useful in anesthesia, critical care, and emergency medicine. Pulse oximeters measure oxygen saturation, spirometers assess lung volumes, and ventilators support breathing but do not measure CO₂ directly. For CBETs, maintaining capnographs involves verifying calibration, sensor performance, and waveform accuracy. Faulty readings could delay recognition of hypoventilation or airway obstruction, posing serious patient risks.

Question 54

A dialysis machine displays “Low Conductivity” alarm. Which of the following is the most likely cause?

Correct answer: B

Explanation

“Low Conductivity” alarms on dialysis machines typically indicate that the electrolyte concentration in the dialysate is below the required level. This usually results from incorrect mixing of acid and bicarbonate concentrates with water, leading to reduced sodium or potassium levels. This condition can be dangerous because it may cause electrolyte imbalances in patients. Blocked blood pumps or broken heparin pumps would cause different alarms. Power supply failure would shut down the machine altogether rather than generate a conductivity alarm. CBETs must verify conductivity with calibration solutions, check mixing systems, and ensure water treatment systems are functioning correctly. Patient safety depends on precise dialysate composition, making this troubleshooting skill critical.

Question 55

An ECG monitor is producing a noisy, artifact-filled trace. What should the CBET check first?

Correct answer: A

Explanation

The most common cause of ECG artifacts is poor electrode placement or inadequate skin preparation. Loose electrodes, dried gel, or oily skin can produce unstable contact, resulting in noisy signals. While amplifier faults or power supply issues could cause problems, they are less common. A CBET should first verify electrodes and cables before moving on to internal circuitry. This systematic approach saves time, prevents unnecessary repairs, and ensures accurate monitoring. Maintaining clean, functional electrodes and cables is a key preventive measure that minimizes ECG signal artifacts.

Question 56

Which hormone regulates blood glucose by promoting uptake of glucose into cells?

Correct answer: B

Explanation

Insulin, secreted by the pancreas, lowers blood glucose by facilitating cellular uptake and storage as glycogen. Glucagon performs the opposite role, raising blood glucose by stimulating glycogen breakdown. Cortisol and epinephrine also elevate blood glucose under stress conditions. For CBETs, understanding glucose regulation is important when servicing blood glucose analyzers, insulin pumps, and continuous glucose monitors (CGMs). Insulin pump accuracy is critical for patients with diabetes, and technicians must verify correct operation of sensors, delivery mechanisms, and alarms. Errors in these devices can directly endanger patient health, making a technician’s physiological knowledge and technical accuracy equally essential.

Question 57

Which medical device measures the partial pressure of oxygen and carbon dioxide in arterial blood?

Correct answer: B

Explanation

An arterial blood gas (ABG) analyzer directly measures arterial pH, partial pressure of oxygen (PaO₂), and partial pressure of carbon dioxide (PaCO₂). These values are essential for assessing a patient’s respiratory and metabolic status. While a pulse oximeter provides non-invasive measurement of oxygen saturation, it cannot measure PaCO₂ or pH. A capnograph measures end-tidal CO₂, useful in monitoring ventilation, but not arterial blood composition. A spirometer measures lung volumes and airflow, not gas exchange. Biomedical technicians ensure ABG analyzers remain accurate by performing calibration, quality control, and troubleshooting sensor or reagent issues. Understanding how these devices work ensures reliable patient diagnostics and effective respiratory care.

Question 58

Which type of blood vessel primarily carries blood away from the heart?

Correct answer: B

Explanation

Arteries carry blood away from the heart, typically oxygenated except for the pulmonary arteries, which carry deoxygenated blood to the lungs. Veins return blood to the heart, capillaries facilitate exchange, and venules are small vessels leading to veins. For CBETs, this distinction is important when calibrating hemodynamic monitoring devices and infusion pumps, which depend on correct vascular pressure and flow measurements.

Question 59

Which law relates the voltage across a capacitor to the rate of change of charge?

Correct answer: D

Explanation

The formula Q = C × V relates the charge (Q) stored on a capacitor to its capacitance (C) and voltage (V). This is fundamental in electronics, as capacitors are widely used to store and release energy. Coulomb’s Law concerns electrostatic force, Kirchhoff’s Laws relate to current/voltage distribution, and Faraday’s Law explains electromagnetic induction. For CBETs, this principle is essential when troubleshooting defibrillators and power supplies where capacitor charge levels must be accurate for safe operation.

Question 60

Which of the following standards governs the exchange of electronic health records (EHRs)?

Correct answer: A

Explanation

Health Level Seven International (HL7) is a set of international standards for the transfer and integration of electronic health records (EHRs). It allows interoperability between medical devices, hospital information systems, and clinical applications. For CBETs, HL7 knowledge is essential because many modern biomedical devices (e.g., vital sign monitors, infusion pumps) interface with EHR systems for automatic data capture. HIPAA governs privacy and security of patient information but does not define data exchange standards. OSHA is workplace safety regulation, and NFPA 99 focuses on healthcare facility electrical safety. A technician must understand HL7 protocols when troubleshooting connectivity issues in networked devices, ensuring medical devices communicate correctly with hospital IT systems while maintaining compliance and patient safety.

0%

Your score on this page: 0/0

Answer the questions above to see your score.

0 of 80 free CBET questions practiced · - overall accuracy

Want the full CBET question bank?

Unlock all 274 questions with mock exam, explanations for every option and domain-level analytics.

Page 6 of 8 · Questions 51-60 of 80 free

PracticeTestMaster is an independent exam prep provider. CBET is the property of Association for the Advancement of Medical Instrumentation (AAMI).

Full access

Unlock all 274 CBET questions

You're practicing 80 free questions. Paid plans add:

  • 194 more exam-style questions
  • Timed mock exam simulations
  • Domain-level score analytics
  • Unlimited reattempts
1 Month $19.99
Buy
12 Months $49.99
Buy
See everything included

Your CBET progress

Questions answered0
Accuracy-

Saved on this device.

CBET exam overview

Exam
Certified Biomedical Equipment Technician (CBET)
Code
CBET
Credential body
Association for the Advancement of Medical Instrumentation (AAMI)
Updated
Nov 24, 2026
Unlock all 274 questionsFrom $19.99
Unlock