Question 31

What is the maximum velocity permitted in copper water distribution piping to prevent erosion?

Correct answer: A

Explanation

To prevent erosion-corrosion in copper piping, velocity is limited to 6 fps for cold water and 5 fps for hot water in most codes. Journeyman exams test this because exceeding velocity limits causes pinhole leaks and system failure.

Question 32

If a 2-inch pipe carries 20 gpm, how many fixture units does this flow rate approximately represent? (1 FU ≈ 7.5 gpm)

Correct answer: C

Explanation

Dividing 20 gpm by 7.5 gpm/FU ≈ 2.67 FU. Codes generally round up, making it 3 FU, but design practices may consider 4 FU for safety. Journeyman exams use these calculations to test a plumber’s ability to size water distribution systems correctly. Proper fixture unit conversion prevents undersized piping.

Question 33

On an isometric drawing, a line labeled with “HWR” represents:

Correct answer: B

Explanation

“HWR” denotes hot water return, part of a recirculating hot water system. Recognizing abbreviations like HWR, CW (cold water), and HW (hot water) is critical to interpreting plumbing isometrics. Journeyman exams test these because accurate reading of plans ensures systems are installed correctly.

Question 34

According to code, a “branch” is defined as:

Correct answer: A

Explanation

A branch is any part of the piping system other than a main, riser, or stack. Journeyman exams test this because accurate terminology ensures clarity in installation and inspection requirements.

Question 35

When performing a water supply test, what is the minimum test pressure required by most plumbing codes?

Correct answer: D

Explanation

Codes require that water supply systems be tested at not less than 150 psi or 50 psi above the working pressure, whichever is greater. The test verifies the integrity of joints, fittings, and materials before the system is placed in service. Journeyman exams test this knowledge because proper testing ensures both safety and compliance.

Question 36

A building drain must be sloped not less than:

Correct answer: C

Explanation

According to code, horizontal drainage piping 2 ½ inches or less must slope at a minimum of 1/4 inch per foot. For larger sizes (4 inches and above), 1/8 inch per foot is acceptable if approved. The purpose of slope is to achieve scouring velocity to carry solids effectively. Too steep of a slope can cause liquids to outrun solids, while insufficient slope causes buildup and blockages. Journeyman plumbers are tested on these values because improper slope design directly affects system performance and sanitary safety.

Question 37

On a plumbing riser diagram, what does a circle with “DF” typically represent?

Correct answer: B

Explanation

“DF” is the standard abbreviation for drinking fountain. Journeyman exams include blueprint reading to ensure candidates can interpret plans accurately and install fixtures as designed.

Question 38

A commercial kitchen sink faucet with a hose spray attachment requires which backflow device?

Correct answer: B

Explanation

Hose attachments on kitchen faucets require atmospheric vacuum breakers to prevent back siphonage. Since these fixtures can be submerged in contaminated water, they are considered moderate hazard. Journeyman exams emphasize proper device selection for food service equipment because of sanitation risk.

Question 39

What is the required maximum hanger spacing for horizontal 2-inch steel pipe?

Correct answer: C

Explanation

Horizontal steel pipe 2 inches in diameter must be supported every 10 feet. Proper support spacing prevents sagging, joint strain, and premature failure. Journeyman exams test hanger spacing because support requirements vary by material and orientation.

Question 40

When air testing a DWV system, what is the minimum test pressure and duration required?

Correct answer: A

Explanation

Code requires that DWV systems under air test be subjected to 3 psi pressure for a duration of 15 minutes with no loss in pressure. This ensures leak-free joints before concealment. Air tests can be hazardous due to stored energy, so strict safety protocols are followed. Water (hydrostatic) tests are often preferred because they pose less risk. Journeyman exams test knowledge of both air and water test procedures, as inspection compliance depends on proper testing methods.

0%

Your score on this page: 0/0

Answer the questions above to see your score.

0 of 80 free Journeyman Plumber questions practiced · - overall accuracy

Want the full Journeyman Plumber question bank?

Unlock all 277 questions with mock exam, explanations for every option and domain-level analytics.

Page 4 of 8 · Questions 31-40 of 80 free

PracticeTestMaster is an independent exam prep provider. Journeyman Plumber is the property of State Licensing Boards.

Full access

Unlock all 277 Journeyman Plumber questions

You're practicing 80 free questions. Paid plans add:

  • 197 more exam-style questions
  • Timed mock exam simulations
  • Domain-level score analytics
  • Unlimited reattempts
1 Month $19.99
Buy
12 Months $49.99
Buy
See everything included

Your Journeyman Plumber progress

Questions answered0
Accuracy-

Saved on this device.

Journeyman Plumber exam overview

Exam
Journeyman Plumber
Code
Journeyman Plumber
Credential body
State Licensing Boards
Updated
Nov 24, 2026
Unlock all 277 questionsFrom $19.99
Unlock