Skip to main content

Free CIH Exam Questions That Helps Candidates Pass - Page 3

CIH Questions 21-30 of 80 free
0/10 answered · 0 correct

Choose an answer and click Check answer to see if you're right, with the full explanation.

Question 21

What does a p-value greater than 0.05 typically suggest?

Correct answer: B

Explanation

p > 0.05 means insufficient evidence to reject the null hypothesis. It does not prove the null true, only lack of evidence. CIHs evaluate statistical and practical significance together.

Question 22

Which calibration device is considered a primary standard for flow measurement?

Correct answer: A

Explanation

Dry bubble meters (and piston provers) are primary standards, providing direct volumetric flow calibration. Mass flow controllers (B), rotameters (C), and electronic flowmeters (D) are secondary standards requiring calibration against a primary device. CIHs use primary standards for defensible calibration of sampling pumps.

Question 23

In ion chromatography, what is measured to quantify anions like chloride?

Correct answer: B

Explanation

Ion chromatography quantifies ions by measuring conductivity changes as they elute. Retention time (A) identifies species but not concentration. UV absorbance (C) applies to aromatic compounds. pH (D) is unrelated. CIHs interpret IC results for workplace monitoring of corrosive gases or mists.

Question 24

Residents near a refinery report sulfur odors. Which compound is most likely responsible?

Correct answer: B

Explanation

Hydrogen sulfide produces a rotten-egg odor detectable at very low concentrations. CO₂ (A) and methane (D) are odorless. Nitric oxide (C) has no strong odor. CIHs confirm with real-time monitoring and odor threshold data.

Question 25

Which detector is most commonly used in gas chromatography for organic solvents?

Correct answer: A

Explanation

FID responds to hydrocarbons with high sensitivity, making it standard for solvents. TCD (B) is universal but less sensitive. MS (C) is powerful but costlier. Electrochemical detectors (D) are for specific analytes. CIHs interpret GC-FID data in solvent exposure cases.

Question 26

Which construction activity is a primary source of respirable crystalline silica?

Correct answer: B

Explanation

Cutting, drilling, or grinding concrete releases respirable silica dust, posing silicosis and lung cancer risks. Painting (A) is not silica-related. Welding (C) may produce hexavalent chromium, not silica. Electrical wiring (D) is unrelated. CIHs implement controls per OSHA’s silica rule: water suppression, ventilation, monitoring, and respirators.

Question 27

A plant IH must characterize solvent vapors (primarily toluene) during a short, high-intensity task lasting 12–15 minutes. Which sampling approach best yields data suitable for comparison to the appropriate exposure limit?

Correct answer: B

Explanation

For short, intense exposures, the occupational exposure metric of concern is typically a short-term exposure limit (STEL) or ceiling value. These limits require time-resolved measurements that can capture rapid concentration changes. A photoionization detector (PID) configured for real-time logging at 1-second intervals provides high temporal resolution, allowing the hygienist to evaluate peak concentrations and compute rolling 15-minute averages aligned with STEL criteria. While an 8-hour integrated charcoal tube (Option A) is excellent for TWA evaluation and laboratory confirmation, it masks short-duration peaks by averaging them over many hours. A 2-hour passive badge (Option C) similarly lacks time resolution and may understate peak intensities. An area sample (Option D) does not represent the worker’s breathing zone and can be confounded by spatial variability and ventilation patterns. The best practice is to pair real-time PID screening with task-based personal sampling when possible; for comparison to numeric standards, ensure instrument calibration with an appropriate span gas, apply response factors for specific analytes like toluene, and document sampling start/stop times to align the dataset precisely with the task window.

Question 28

Which lab method is standard for analyzing airborne metal samples collected on filters?

Correct answer: B

Explanation

AAS and ICP-AES are standard for metal quantification from filter digests. GC-FID (A) is for organics. UV-Vis (C) applies in some colorimetric methods but less common for metals. Ion selective electrodes (D) are specific to certain ions in solutions, not airborne particulates.

Question 29

Which principle underlies atomic emission spectroscopy (AES)?

Correct answer: B

Explanation

AES measures light emitted by excited atoms returning to ground state. Absorption (A) applies to AAS. Ionization (C) applies in MS. Chromatography (D) separates compounds, not emission. CIHs rely on AES/ICP for metals analysis.

Question 30

Which dosimeter provides the most accurate measurement of cumulative whole-body dose over months?

Correct answer: C

Explanation

TLDs store energy from ionizing radiation in crystal lattices, released as light upon heating, giving precise cumulative dose over weeks to months. Pocket ion chambers (A) provide immediate readings but can drift. Film badges (B) are older, less precise, and sensitive to environmental factors. Real-time dosimeters (D) are useful for instant feedback but not long-term integration. CIHs select TLDs for regulatory monitoring, backed by QA programs and calibration.

0%

Your score on this page: 0/0

Answer the questions above to see your score.

0 of 80 free CIH questions practiced · - overall accuracy

Want the full CIH question bank?

Unlock all 248 questions with mock exam, explanations for every option and domain-level analytics.

Page 3 of 8 · Questions 21-30 of 80 free

PracticeTestMaster is an independent exam prep provider. CIH is the property of American Board of Industrial Hygiene (ABIH).

Full access

Unlock all 248 CIH questions

You're practicing 80 free questions. Paid plans add:

  • 168 more exam-style questions
  • Timed mock exam simulations
  • Domain-level score analytics
  • Unlimited reattempts
1 Month $19.99
Buy
12 Months $49.99
Buy
See everything included

Your CIH progress

Questions answered0
Accuracy-

Saved on this device.

CIH exam overview

Exam
Certified Industrial Hygienist
Code
CIH
Credential body
American Board of Industrial Hygiene (ABIH)
Updated
Nov 24, 2026
Unlock all 248 questionsFrom $19.99
Unlock